Review




Structured Review

Phenix Research Products non-vented 8 strip caps for and macro tubes
Non Vented 8 Strip Caps For And Macro Tubes, supplied by Phenix Research Products, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/non-vented+8+strip+caps+for+and+macro+tubes/non+vented+8+strip+caps+for+and+macro+tubes/pmc10119968-4-254-256
Average 90 stars, based on 1 article reviews
non-vented 8 strip caps for and macro tubes - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

Stripping Membranes:

Article Title: Rapid determination of protein digestibility in sorghum before and after cooking
Article Snippet: •1 mL 96 deep well plate (Beckman Coulter, Cat. No. 267001). .. •Non-vented 8 strip caps for 0.65 mL and 1.1 mL macro tubes (Phenix Research Products, Cat. No. M-948C). ..

Article Title: Rapid determination of protein digestibility in sorghum before and after cooking
Article Snippet: .. Resource availability: , Seed material • Sorghum seeds totaling ∼60 mg or a piece of maize endosperm weighing ∼60 mg. Keeping input material at approximately the same weights is important for comparison. Reagents • Potassium Phosphate Monobasic (Fisher Scientific, Cat. No. P285) • Sodium Hydroxide (NaOH; Macron Chemicals, Cat. No. 7706) Note: NaOH is caustic; wear proper protection. • Sodium Tetraborate Decahydrate (Na2B4O7; Sigma-Aldrich, Cat. No. S9640) • Sodium Dodecyl Sulfate (SDS; Sigma-Aldrich, Cat. No. L3771) • Pepsin (Macron Chemicals, Cat. No. 2629-57, activity 3300 U/mg of protein) • 2-Mercaptoethanol (BME; JT Baker, Cat. No. 4049-00) Note: BME is toxic; must be used in a fume hood with proper protective equipment. • Trichloroacetic Acid (TCA; VWR, Cat. No. BDH9310) Note: TCA is caustic and a suspected carcinogen; use in a fume hood and wear proper protective equipment. Equipment • 2mL reinforced polypropylene tubes with screw caps and silicone O-rings (Omni International, Cat. No. 19-649) • 2.8 mm ceramic beads (Omni International, Cat. No. 19-646) • Multi-Channel micropipettes (Rainin LTS; L-20, L-300 XLS, L-1200 XLS) • Bead Grinder capable of grinding sorghum seeds (Omni International, Bead Ruptor 24) • Rotating oven capable of reaching 95°C and holding 1.5 ml tube rack • Tabletop vortex • Single channel micropipette (Rainin LTS, L-200) • Nuclease-free 1000 μL, 300 μL, 200 μL, and 20 μL regular tips • Nuclease-free 250 μL wide bore micropipette tips • 1 mL 96 deep well plate (Beckman Coulter, Cat. No. 267001) • Non-vented 8 strip caps for 0.65 mL and 1.1 mL macro tubes (Phenix Research Products, Cat. No. M-948C) • Refrigerator capable of storing samples at 4°C • pH meter (Beckman Coulter, Cat. No. 511212) • Centrifuge capable of holding deep well plates (Eppendorf; Centrifuge 5804 with rotor A-2-DWP) • Multi Tube/plate Vortexer (VWR, Cat. No. VX-2500) • Fume Hood • Shaker Incubator capable of maintaining 25°C (New Brunswick Scientific, C24 Incubator Shaker). Note: Room temperature can be highly variable, and a heated shaker in a cold room or refrigerator cabinet works the most consistently. • Clear flat bottom 350 μL 96 well plate (VWR, Cat. No. 89093-592) • Plate reader capable of reading absorbances at 562 nm (BioTek, BioTek ELx800) • Computer capable of running BioTek Gen5 software for plate absorbance analysis.. ..

Comparison:

Article Title: Rapid determination of protein digestibility in sorghum before and after cooking
Article Snippet: .. Resource availability: , Seed material • Sorghum seeds totaling ∼60 mg or a piece of maize endosperm weighing ∼60 mg. Keeping input material at approximately the same weights is important for comparison. Reagents • Potassium Phosphate Monobasic (Fisher Scientific, Cat. No. P285) • Sodium Hydroxide (NaOH; Macron Chemicals, Cat. No. 7706) Note: NaOH is caustic; wear proper protection. • Sodium Tetraborate Decahydrate (Na2B4O7; Sigma-Aldrich, Cat. No. S9640) • Sodium Dodecyl Sulfate (SDS; Sigma-Aldrich, Cat. No. L3771) • Pepsin (Macron Chemicals, Cat. No. 2629-57, activity 3300 U/mg of protein) • 2-Mercaptoethanol (BME; JT Baker, Cat. No. 4049-00) Note: BME is toxic; must be used in a fume hood with proper protective equipment. • Trichloroacetic Acid (TCA; VWR, Cat. No. BDH9310) Note: TCA is caustic and a suspected carcinogen; use in a fume hood and wear proper protective equipment. Equipment • 2mL reinforced polypropylene tubes with screw caps and silicone O-rings (Omni International, Cat. No. 19-649) • 2.8 mm ceramic beads (Omni International, Cat. No. 19-646) • Multi-Channel micropipettes (Rainin LTS; L-20, L-300 XLS, L-1200 XLS) • Bead Grinder capable of grinding sorghum seeds (Omni International, Bead Ruptor 24) • Rotating oven capable of reaching 95°C and holding 1.5 ml tube rack • Tabletop vortex • Single channel micropipette (Rainin LTS, L-200) • Nuclease-free 1000 μL, 300 μL, 200 μL, and 20 μL regular tips • Nuclease-free 250 μL wide bore micropipette tips • 1 mL 96 deep well plate (Beckman Coulter, Cat. No. 267001) • Non-vented 8 strip caps for 0.65 mL and 1.1 mL macro tubes (Phenix Research Products, Cat. No. M-948C) • Refrigerator capable of storing samples at 4°C • pH meter (Beckman Coulter, Cat. No. 511212) • Centrifuge capable of holding deep well plates (Eppendorf; Centrifuge 5804 with rotor A-2-DWP) • Multi Tube/plate Vortexer (VWR, Cat. No. VX-2500) • Fume Hood • Shaker Incubator capable of maintaining 25°C (New Brunswick Scientific, C24 Incubator Shaker). Note: Room temperature can be highly variable, and a heated shaker in a cold room or refrigerator cabinet works the most consistently. • Clear flat bottom 350 μL 96 well plate (VWR, Cat. No. 89093-592) • Plate reader capable of reading absorbances at 562 nm (BioTek, BioTek ELx800) • Computer capable of running BioTek Gen5 software for plate absorbance analysis.. ..

Activity Assay:

Article Title: Rapid determination of protein digestibility in sorghum before and after cooking
Article Snippet: .. Resource availability: , Seed material • Sorghum seeds totaling ∼60 mg or a piece of maize endosperm weighing ∼60 mg. Keeping input material at approximately the same weights is important for comparison. Reagents • Potassium Phosphate Monobasic (Fisher Scientific, Cat. No. P285) • Sodium Hydroxide (NaOH; Macron Chemicals, Cat. No. 7706) Note: NaOH is caustic; wear proper protection. • Sodium Tetraborate Decahydrate (Na2B4O7; Sigma-Aldrich, Cat. No. S9640) • Sodium Dodecyl Sulfate (SDS; Sigma-Aldrich, Cat. No. L3771) • Pepsin (Macron Chemicals, Cat. No. 2629-57, activity 3300 U/mg of protein) • 2-Mercaptoethanol (BME; JT Baker, Cat. No. 4049-00) Note: BME is toxic; must be used in a fume hood with proper protective equipment. • Trichloroacetic Acid (TCA; VWR, Cat. No. BDH9310) Note: TCA is caustic and a suspected carcinogen; use in a fume hood and wear proper protective equipment. Equipment • 2mL reinforced polypropylene tubes with screw caps and silicone O-rings (Omni International, Cat. No. 19-649) • 2.8 mm ceramic beads (Omni International, Cat. No. 19-646) • Multi-Channel micropipettes (Rainin LTS; L-20, L-300 XLS, L-1200 XLS) • Bead Grinder capable of grinding sorghum seeds (Omni International, Bead Ruptor 24) • Rotating oven capable of reaching 95°C and holding 1.5 ml tube rack • Tabletop vortex • Single channel micropipette (Rainin LTS, L-200) • Nuclease-free 1000 μL, 300 μL, 200 μL, and 20 μL regular tips • Nuclease-free 250 μL wide bore micropipette tips • 1 mL 96 deep well plate (Beckman Coulter, Cat. No. 267001) • Non-vented 8 strip caps for 0.65 mL and 1.1 mL macro tubes (Phenix Research Products, Cat. No. M-948C) • Refrigerator capable of storing samples at 4°C • pH meter (Beckman Coulter, Cat. No. 511212) • Centrifuge capable of holding deep well plates (Eppendorf; Centrifuge 5804 with rotor A-2-DWP) • Multi Tube/plate Vortexer (VWR, Cat. No. VX-2500) • Fume Hood • Shaker Incubator capable of maintaining 25°C (New Brunswick Scientific, C24 Incubator Shaker). Note: Room temperature can be highly variable, and a heated shaker in a cold room or refrigerator cabinet works the most consistently. • Clear flat bottom 350 μL 96 well plate (VWR, Cat. No. 89093-592) • Plate reader capable of reading absorbances at 562 nm (BioTek, BioTek ELx800) • Computer capable of running BioTek Gen5 software for plate absorbance analysis.. ..

Hood:

Article Title: Rapid determination of protein digestibility in sorghum before and after cooking
Article Snippet: .. Resource availability: , Seed material • Sorghum seeds totaling ∼60 mg or a piece of maize endosperm weighing ∼60 mg. Keeping input material at approximately the same weights is important for comparison. Reagents • Potassium Phosphate Monobasic (Fisher Scientific, Cat. No. P285) • Sodium Hydroxide (NaOH; Macron Chemicals, Cat. No. 7706) Note: NaOH is caustic; wear proper protection. • Sodium Tetraborate Decahydrate (Na2B4O7; Sigma-Aldrich, Cat. No. S9640) • Sodium Dodecyl Sulfate (SDS; Sigma-Aldrich, Cat. No. L3771) • Pepsin (Macron Chemicals, Cat. No. 2629-57, activity 3300 U/mg of protein) • 2-Mercaptoethanol (BME; JT Baker, Cat. No. 4049-00) Note: BME is toxic; must be used in a fume hood with proper protective equipment. • Trichloroacetic Acid (TCA; VWR, Cat. No. BDH9310) Note: TCA is caustic and a suspected carcinogen; use in a fume hood and wear proper protective equipment. Equipment • 2mL reinforced polypropylene tubes with screw caps and silicone O-rings (Omni International, Cat. No. 19-649) • 2.8 mm ceramic beads (Omni International, Cat. No. 19-646) • Multi-Channel micropipettes (Rainin LTS; L-20, L-300 XLS, L-1200 XLS) • Bead Grinder capable of grinding sorghum seeds (Omni International, Bead Ruptor 24) • Rotating oven capable of reaching 95°C and holding 1.5 ml tube rack • Tabletop vortex • Single channel micropipette (Rainin LTS, L-200) • Nuclease-free 1000 μL, 300 μL, 200 μL, and 20 μL regular tips • Nuclease-free 250 μL wide bore micropipette tips • 1 mL 96 deep well plate (Beckman Coulter, Cat. No. 267001) • Non-vented 8 strip caps for 0.65 mL and 1.1 mL macro tubes (Phenix Research Products, Cat. No. M-948C) • Refrigerator capable of storing samples at 4°C • pH meter (Beckman Coulter, Cat. No. 511212) • Centrifuge capable of holding deep well plates (Eppendorf; Centrifuge 5804 with rotor A-2-DWP) • Multi Tube/plate Vortexer (VWR, Cat. No. VX-2500) • Fume Hood • Shaker Incubator capable of maintaining 25°C (New Brunswick Scientific, C24 Incubator Shaker). Note: Room temperature can be highly variable, and a heated shaker in a cold room or refrigerator cabinet works the most consistently. • Clear flat bottom 350 μL 96 well plate (VWR, Cat. No. 89093-592) • Plate reader capable of reading absorbances at 562 nm (BioTek, BioTek ELx800) • Computer capable of running BioTek Gen5 software for plate absorbance analysis.. ..

Software:

Article Title: Rapid determination of protein digestibility in sorghum before and after cooking
Article Snippet: .. Resource availability: , Seed material • Sorghum seeds totaling ∼60 mg or a piece of maize endosperm weighing ∼60 mg. Keeping input material at approximately the same weights is important for comparison. Reagents • Potassium Phosphate Monobasic (Fisher Scientific, Cat. No. P285) • Sodium Hydroxide (NaOH; Macron Chemicals, Cat. No. 7706) Note: NaOH is caustic; wear proper protection. • Sodium Tetraborate Decahydrate (Na2B4O7; Sigma-Aldrich, Cat. No. S9640) • Sodium Dodecyl Sulfate (SDS; Sigma-Aldrich, Cat. No. L3771) • Pepsin (Macron Chemicals, Cat. No. 2629-57, activity 3300 U/mg of protein) • 2-Mercaptoethanol (BME; JT Baker, Cat. No. 4049-00) Note: BME is toxic; must be used in a fume hood with proper protective equipment. • Trichloroacetic Acid (TCA; VWR, Cat. No. BDH9310) Note: TCA is caustic and a suspected carcinogen; use in a fume hood and wear proper protective equipment. Equipment • 2mL reinforced polypropylene tubes with screw caps and silicone O-rings (Omni International, Cat. No. 19-649) • 2.8 mm ceramic beads (Omni International, Cat. No. 19-646) • Multi-Channel micropipettes (Rainin LTS; L-20, L-300 XLS, L-1200 XLS) • Bead Grinder capable of grinding sorghum seeds (Omni International, Bead Ruptor 24) • Rotating oven capable of reaching 95°C and holding 1.5 ml tube rack • Tabletop vortex • Single channel micropipette (Rainin LTS, L-200) • Nuclease-free 1000 μL, 300 μL, 200 μL, and 20 μL regular tips • Nuclease-free 250 μL wide bore micropipette tips • 1 mL 96 deep well plate (Beckman Coulter, Cat. No. 267001) • Non-vented 8 strip caps for 0.65 mL and 1.1 mL macro tubes (Phenix Research Products, Cat. No. M-948C) • Refrigerator capable of storing samples at 4°C • pH meter (Beckman Coulter, Cat. No. 511212) • Centrifuge capable of holding deep well plates (Eppendorf; Centrifuge 5804 with rotor A-2-DWP) • Multi Tube/plate Vortexer (VWR, Cat. No. VX-2500) • Fume Hood • Shaker Incubator capable of maintaining 25°C (New Brunswick Scientific, C24 Incubator Shaker). Note: Room temperature can be highly variable, and a heated shaker in a cold room or refrigerator cabinet works the most consistently. • Clear flat bottom 350 μL 96 well plate (VWR, Cat. No. 89093-592) • Plate reader capable of reading absorbances at 562 nm (BioTek, BioTek ELx800) • Computer capable of running BioTek Gen5 software for plate absorbance analysis.. ..



Similar Products

90
Phenix Research Products non-vented 8 strip caps for and macro tubes
Non Vented 8 Strip Caps For And Macro Tubes, supplied by Phenix Research Products, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/non-vented+8+strip+caps+for+and+macro+tubes/non+vented+8+strip+caps+for+and+macro+tubes/pmc10119968-4-254-256
Average 90 stars, based on 1 article reviews
non-vented 8 strip caps for and macro tubes - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results